1.
Sensors (Basel) ; 22(10)2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35632246

RESUMO

A novel multicore optical waveguide component based on a fiber design optimized towards selective grating inscription for multiplexed sensing applications is presented. Such a fiber design enables the increase in the optical sensor capacity as well as extending the sensing length with a single optical fiber while preserving the spatial sensing resolution. The method uses a multicore fiber with differently doped fiber cores and, therefore, enables a selective grating inscription. The concept can be applied in a draw tower inscription process for an efficient production of sensing networks. Along with the general concept, the paper discusses the specific preparation of the fiber-based sensing component and provides experimental results showing the feasibility of such a sensing system.

2.
Opt Express ; 29(18): 28778-28786, 2021 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-34615000

RESUMO

Here, we present the thermal tuning capability of an alignment-free, fiber-integrated Fabry-Pérot cavity. The two mirrors are made of fiber Bragg gratings that can be individually temperature stabilized and tuned. We show the temperature tuning of the resonance wavelength of the cavity without any degradation of the finesse and the tuning of the individual stop bands of the fiber Bragg gratings. This not only permits for the cavity's finesse to be optimized post-fabrication but also makes this cavity applicable as a narrowband filter with a FWHM spectral width of 0.07 ± 0.02 pm and a suppression of more than -15 dB that can be wavelength tuned. Further, in the field of quantum optics, where strong light-matter interactions are desirable, quantum emitters can be coupled to such a cavity and the cavity effect can be reversibly omitted and re-established. This is particularly useful when working with solid-state quantum emitters where such a reference measurement is often not possible once an emitter has been permanently deposited inside a cavity.

3.
Sci Rep ; 10(1): 19313, 2020 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-33168867

RESUMO

The optical Vernier effect consists of overlapping responses of a sensing and a reference interferometer with slightly shifted interferometric frequencies. The beating modulation thus generated presents high magnified sensitivity and resolution compared to the sensing interferometer, if the two interferometers are slightly out of tune with each other. However, the outcome of such a condition is a large beating modulation, immeasurable by conventional detection systems due to practical limitations of the usable spectral range. We propose a method to surpass this limitation by using a few-mode sensing interferometer instead of a single-mode one. The overlap response of the different modes produces a measurable envelope, whilst preserving an extremely high magnification factor, an order of magnification higher than current state-of-the-art performances. Furthermore, we demonstrate the application of that method in the development of a giant sensitivity fibre refractometer with a sensitivity of around 500 µm/RIU (refractive index unit) and with a magnification factor over 850.

4.
Opt Express ; 28(3): 3249-3257, 2020 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-32121997

RESUMO

We demonstrate a cryo-compatible, fully fiber-integrated, alignment-free optical microresonator. The compatibility with low temperatures expands its possible applications to the wide field of solid-state quantum optics, where a cryogenic environment is often a requirement. At a temperature of 4.6 K we obtain a quality factor of (9.9 ± 0.7) × 106. In conjunction with the small mode volume provided by the nanofiber, this cavity can be either used in the coherent dynamics or the fast cavity regime, where it can provide a Purcell factor of up to 15. Our resonator is therefore suitable for significantly enhancing the coupling between light and a large variety of different quantum emitters and due to its proven performance over a wide temperature range, also lends itself for the implementation of quantum hybrid systems.

5.
Sensors (Basel) ; 19(24)2019 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-31835433

RESUMO

The optical Vernier effect magnifies the sensing capabilities of an interferometer, allowing for unprecedented sensitivities and resolutions to be achieved. Just like a caliper uses two different scales to achieve higher resolution measurements, the optical Vernier effect is based on the overlap in the responses of two interferometers with slightly detuned interference signals. Here, we present a novel approach in detail, which introduces optical harmonics to the Vernier effect through Fabry-Perot interferometers, where the two interferometers can have very different frequencies in the interferometric pattern. We demonstrate not only a considerable enhancement compared to current methods, but also better control of the sensitivity magnification factor, which scales up with the order of the harmonics, allowing us to surpass the limits of the conventional Vernier effect as used today. In addition, this novel concept opens also new ways of dimensioning the sensing structures, together with improved fabrication tolerances.

6.
Sensors (Basel) ; 19(3)2019 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-30678290

RESUMO

New miniaturized sensors for biological and medical applications must be adapted to the measuring environments and they should provide a high measurement resolution to sense small changes. The Vernier effect is an effective way of magnifying the sensitivity of a device, allowing for higher resolution sensing. We applied this concept to the development of a small-size optical fiber Fabry⁻Perot interferometer probe that presents more than 60-fold higher sensitivity to temperature than the normal Fabry⁻Perot interferometer without the Vernier effect. This enables the sensor to reach higher temperature resolutions. The silica Fabry⁻Perot interferometer is created by focused ion beam milling of the end of a tapered multimode fiber. Multiple Fabry⁻Perot interferometers with shifted frequencies are generated in the cavity due to the presence of multiple modes. The reflection spectrum shows two main components in the Fast Fourier transform that give rise to the Vernier effect. The superposition of these components presents an enhancement of sensitivity to temperature. The same effect is also obtained by monitoring the reflection spectrum node without any filtering. A temperature sensitivity of -654 pm/°C was obtained between 30 °C and 120 °C, with an experimental resolution of 0.14 °C. Stability measurements are also reported.

7.
Opt Express ; 25(22): 26393-26404, 2017 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-29092130

RESUMO

We present a fiber-integrated laser enabling independent tuning of two emission wavelengths with a synchronized pulsed emission. The discrete tuning concept comprises a theta cavity fiber laser (TCFL), a fiber Bragg grating (FBG) array as a versatile spectral filter, facilitating tailored tuning ranges, and optical gating to control the emission spectrum. A novel electrical driving scheme uniquely enables independently tunable multi-wavelength emission from a single laser oscillator. Tunable dual-wavelength emission is experimentally investigated with a ytterbium (Yb)-doped TCFL using an FBG array with 11 gratings. Over a tuning range of 25 nm, 55 wavelength pairs have been demonstrated with high signal contrast (≈ 40 dB) and narrow linewidth (< 40GHz). Based on the demands of prospective applications, pulse synchronicity is studied with a fiber-based time-delay spectrometer (TDS) simultaneously measuring the joint temporal and spectral pulse properties down to a single-pulse analysis. Accordingly, tunable and fully synchronized dual-wavelength emissions have been verified by driving the TCFL with optimized electrical gating parameters. This unique operation mode achieved in a cost-efficient fiber-integrated laser design targets novel applications e.g. in nonlinear spectroscopy and biophotonics.

8.
Opt Lett ; 42(6): 1125-1128, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-28295064

RESUMO

We demonstrate a novel tuning concept for pulsed fiber-integrated lasers with a fiber Bragg grating (FBG) array as a discrete and tailored spectral filter, as well as a modified laser design. Based on a theta cavity layout, the structural delay lines originating from the FBG array are balanced, enabling a constant repetition rate and stable pulse properties over the full tuning range. The emission wavelength is electrically tuned with respect to the filter properties based on an adapted temporal gating scheme using an acousto-optic modulator. This concept has been investigated with an Yb-doped fiber laser, demonstrating excellent emission properties with high signal contrast (>35 dB) and narrow linewidth (<150 pm) over a tuning range of 25 nm.

9.
Opt Express ; 24(13): 14053-65, 2016 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-27410566

RESUMO

Optical fiber micro-tips are promising devices for sensing applications in small volume and difficult to access locations, such as biological and biomedical settings. The tapered fiber tips are prepared by dynamic chemical etching, reducing the size from 125 µm to just a few µm. Focused ion beam milling is then used to create cavity structures on the tapered fiber tips. Two different Fabry-Perot micro-cavities have been prepared and characterized: a solid silica cavity created by milling two thin slots and a gap cavity. A third multi-cavity structure is fabricated by combining the concepts of solid silica cavity and gap cavity. This micro-tip structure is analyzed using a fast Fourier transform method to demultiplex the signals of each cavity. Simultaneous measurement of temperature and external refractive index is then demonstrated, presenting sensitivities of - 15.8 pm/K and -1316 nm/RIU, respectively.

10.
Opt Lett ; 41(8): 1885-8, 2016 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-27082370

RESUMO

We present a femtosecond laser system delivering up to 100 W of average power at 343 nm. The laser system employs a Yb-based femtosecond fiber laser and subsequent second- and third-harmonic generation in beta barium borate (BBO) crystals. Thermal gradients within these BBO crystals are mitigated by sapphire heat spreaders directly bonded to the front and back surface of the crystals. Thus, a nearly diffraction-limited beam quality (M2 < 1.4) is achieved, despite the high thermal load to the nonlinear crystals. This laser source is expected to push many industrial and scientific applications in the future.

11.
Opt Express ; 23(20): 25972-8, 2015 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-26480112

RESUMO

Acousto-optic modulation of a 1 cm fiber Bragg grating at 10.9 MHz frequency and 1065 nm wavelength is demonstrated for the first time. A special modulator design is employed to acoustically induce a dynamic radial long period grating which couples power of the fundamental mode to the higher-order modes supported by the Bragg grating. A modulated reflection band with a depth of 16 dB and 320 pm bandwidth has been achieved. The results indicate a higher modulation frequency compared to previous studies using flexural acoustic waves. In addition, the reduction of the grating length and the modulator size points to compact and faster acousto-optic modulators.

12.
Opt Express ; 23(15): 19634-45, 2015 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-26367621

RESUMO

We present a novel method to discretely tune the emission wavelength of pulsed fiber-integrated lasers. As spectral filter, a step-chirped fiber Bragg grating (FBG) array is employed combining a monolithic structure with an unrivaled design freedom enabling large tuning bandwidths as well as tailored spectral characteristics towards fingerprint tuning features. Together with an electrical control mechanism ensuring programmable operation, this tuning method promotes fiber-integrated lasers to access new fields of applications e.g. in biophotonics and distributed sensing. The potential of this tuning concept is investigated based on an Ytterbium-doped fiber laser. The system shows superb emission properties including excellent wavelength stability, high spectral signal contrast (up to 50dB) and narrow linewidth (15GHz) as well as adjustable pulse durations in the nanosecond range with peak powers up to 100W. Additionally, the unique spectral potential of this method is demonstrated by realizing filter designs enabling e.g. a record tuning range of 74nm for fiber-integrated lasers.

13.
Opt Express ; 22(22): 26825-33, 2014 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-25401829

RESUMO

A structured sapphire-derived all-glass optical fiber with an aluminum content in the core of up to 50 mol% was used for fiber Bragg grating inscription. The fiber provided a parabolic refractive index profile. Fiber Bragg gratings were inscribed by means of femtosecond-laser pulses with a wavelength of 400 nm in combination with a two-beam phase mask interferometer. Heating experiments demonstrated the stability of the gratings for temperatures up to 950°C for more than 24 h without degradation in reflectivity.

14.
Sensors (Basel) ; 14(9): 15786-801, 2014 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-25157554

RESUMO

Along with the dose rate and the total irradiation dose measurements, the knowledge of the beam localization and the beam profile/energy distribution in the beam are parameters of interest for charged particle accelerator installations when they are used in scientific investigations, industrial applications or medical treatments. The transverse profile of the beam, its position, its centroid location, and its focus or flatness depend on the instrument operating conditions or on the beam exit setup. Proof-of-concept of a new type of charged particle beam diagnostics based on fiber Bragg gratings (FBGs) was demonstrated. Its operating principle relies on the measurement of the peak wavelength changes for an array of FBG sensors as function of the temperature following the exposure to an electron beam. Periodically, the sensor irradiation is stopped and the FBG are force cooled to a reference temperature with which the temperature influencing each sensor during beam exposure is compared. Commercially available FBGs, and FBGs written in radiation resistant optical fibers, were tested under electron beam irradiation in order to study their possible use in this application.


Assuntos
Elétrons , Tecnologia de Fibra Óptica/instrumentação , Radiometria/instrumentação , Refratometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação
15.
Opt Express ; 22(11): 13102-8, 2014 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-24921506

RESUMO

Focused ion beam technology is combined with chemical etching of specifically designed fibers to create Fabry-Perot interferometers. Hydrofluoric acid is used to etch special fibers and create microwires with diameters of 15 µm. These microwires are then milled with a focused ion beam to create two different structures: an indented Fabry-Perot structure and a cantilever Fabry-Perot structure that are characterized in terms of temperature. The cantilever structure is also sensitive to vibrations and is capable of measuring frequencies in the range 1 Hz - 40 kHz.

16.
Opt Lett ; 38(13): 2224-6, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23811884

RESUMO

In this Letter, we present the technology of fiber Bragg grating (FBG) inscription in highly birefringent (HB) few-mode microstructured fibers (MSFs) with two different (nanosecond and femtosecond) lasers in a Talbot interferometer setup. The spectral characteristics of FBGs written in the core region of the investigated fiber, with particular modes represented by dual peaks, are presented and discussed. Furthermore, we calculate the fundamental fiber parameters (mode effective refractive index and phase modal birefringence) from the spectral characteristics and show very good agreement with the performed numerical fiber characterization. We expect the results of our experiments to be very useful in future development of FBG sensors based on novel HB MSFs, with enhanced strain sensitivity of higher-order modes.

17.
Opt Express ; 21(4): 4591-7, 2013 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-23481992

RESUMO

The paper describes the implementation of fiber Bragg gratings inscribed by femtosecond laser pulses with a wavelength of 400 nm. The use of a Talbot interferometer for the inscription process makes multiplexing practicable. We demonstrate the functionality of a three-grating multiplexing sensor and the temperature stability up to 1200 °C for a single first-order Bragg grating.


Assuntos
Óxido de Alumínio/química , Lasers , Ressonância de Plasmônio de Superfície/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Propriedades de Superfície/efeitos da radiação
18.
Opt Lett ; 38(5): 676-8, 2013 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-23455262

RESUMO

We demonstrate the inscription of a 266 nm UV femtosecond pulse-induced fiber Bragg grating (FBG) in an Yb-doped fiber during optical pumping at 976 nm and the initiation of lasing with increasing grating reflectivity. Output spectra show the emission of the pumped fiber changing from the broad-ranged amplified spontaneous emission in the nonlasing case to the narrow-range laser operation due to the enhancement of FBG reflectivity during inscription. The proposed technique enables the direct characterization and control of FBG performance in fiber lasers. After FBG fabrication, we investigate the spectral characteristics of the fiber laser for different laser powers and study the influence of a thermal treatment of the FBG.

19.
Appl Opt ; 52(6): 1161-7, 2013 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-23434986

RESUMO

We have realized a modified time-delay spectrometer based on a step-chirped fiber Bragg grating array. This method allows simultaneous spectral and temporal characterization of pulsed light sources in the nanosecond regime, which can also be applied to the investigation of single pulses. With a spectral resolution in the 100 pm range, pulse spectrograms are measured and exemplarily used to explore the emission behavior of a wavelength-stabilized laser diode directly modulated in the nanosecond range.

20.
Lab Chip ; 13(6): 1109-13, 2013 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-23344502

RESUMO

An all-fibre based Raman-on-chip setup is introduced which enables analysis of solutions and trapped particles without microscopes or objectives. Beside the novel quartz microfluidic chip, innovative multi-core single-mode fibres with integrated fibre Bragg gratings are used for detection. The limit of quantitation is 7.5 mM for urea and 2.5 mM for nicotine with linear Raman spectroscopy. This is an improvement of more than two orders of magnitude compared with previous fibre-based microfluidic Raman detection schemes. Furthermore, our device was combined with optical traps to collect Raman-on-chip spectra of spherical polymer beads.